Friday, July 26, 2013
Unregulated Power Supply
A basic full wave rectified power supply is shown below. The transformer is chosen according to the desired load. For example, if the load requires 12V at 1amp current, then a 12V, 1 amp rated transformer would do. However, when designing power supplies or most electronic circuits, you should always plan for a worst case scenario. With this in mind, for a load current of 1 amp a wise choice would be a transformer with a secondary current rating of 1.5 amp or even 2 amps. Allowing for a load of 50% higher than the needed value is a good rule of thumb. The primary winding is always matched to the value of the local electricity supply.
An approximate formula for determining the amount of ripple on an unregulated supply is:
The calculated value of ripple is (0.1 * 0.007) / 1000e-6 = 0.7 volts or 700mV. The value of peak-peak ripple measured from the graph is 628mV. Therefor, the equation is a good rule of thumb guide for choosing the correct value for a smoothing capacitor in a power supply. Advertisement:
Subscribe to:
Post Comments (Atom)
No comments:
Post a Comment
Note: Only a member of this blog may post a comment.